ADE7768
Table 5. F 1–4 Frequency Selection
Table 7. Maximum Output Frequency on CF
S1
0
0
1
1
S0
0
1
0
1
OSC Relation
OSC/2 19
OSC/2 18
OSC/2 17
OSC/2 16
1
F 1–4 at Nominal OSC (Hz)
0.86
1.72
3.43
6.86
2
SCF
1
0
1
0
S1
0
0
0
0
S0
0
0
1
1
CF Max for AC Signals (Hz) 1
128 × F1, F2 = 22.4
64 × F1, F2 = 11.2
64 × F1, F2 = 22.4
32 × F1, F2 = 11.2
1
2
F 1–4 is a binary fraction of the internal oscillator frequency.
Values are generated using the nominal frequency of 450 kHz.
1
0
1
1
0
0
32 × F1, F2 = 22.4
16 × F1, F2 = 11.2
Values are generated using the nominal frequency of 450 kHz.
Example
In this example, with ac voltages of ±30 mV peak applied to
V1 and ±165 mV peak applied to V2, the expected output
frequency is calculated as follows:
F 1–4 = OSC/2 19 Hz, S0 = S1 = 0
V1 rms = 0.03/√2 V
V2 rms = 0.165/√2 V
V REF = 2.45 V (nominal reference value)
Note that if the on-chip reference is used, actual output
frequencies may vary from device to device due to the
reference tolerance of ±200 mV.
1 1 1 16 × F1, F2 = 22.4
0 1 1 2048 × F1, F2 = 2.867 kHz
1
SELECTING A FREQUENCY FOR AN ENERGY
METER APPLICATION
As shown in Table 5, the user can select one of four frequencies.
This frequency selection determines the maximum frequency
on F1 and F2. These outputs are intended for driving an energy
register (electromechanical or other). Because only four
different output frequencies can be selected, the available
frequency selection has been optimized for a meter constant
of 100 imp/kWh with a maximum current of between 10 A
Freq =
494 . 75 × 0 . 03 × 0 . 165 × F 1
2 × 2 × 2 . 45 2
= 0 . 204 × F 1 = 0 . 175
(11)
and 120 A. Table 8 shows the output frequency for several
maximum currents (I MAX ) with a line voltage of 220 V. In all
cases, the meter constant is 100 imp/kWh.
Table 6. Maximum Output Frequency on F1 and F2
Table 8. F1 and F2 Frequency at 100 imp/kWh
Max Frequency or AC Inputs (Hz)
S1
0
0
1
1
S0
0
1
0
1
OSC Relation
0.204 × F 1
0.204 × F 2
0.204 × F 3
0.204 × F 4
0.175
0.35
0.70
1.40
1
I MAX (A)
12.5
25.0
40.0
60.0
F1 and F2 (Hz)
0.076
0.153
0.244
0.367
Values are generated using the nominal frequency of 450 kHz.
1
Frequency Output CF
80.0
120.0
0.489
0.733
The pulse output CF (calibration frequency) is intended for
calibration purposes. The output pulse rate on CF can be up
to 2048 times the pulse rate on F1 and F2. The lower the F 1–4
frequency selected, the higher the CF scaling (except for the
high frequency mode SCF = 0, S1 = S0 = 1). Table 7 shows
how the two frequencies are related, depending on the states
of the logic inputs S0, S1, and SCF. Due to its relatively high
pulse rate, the frequency at the CF logic output is proportional
to the instantaneous positive-only real power. As with F1 and
F2, CF is derived from the output of the low-pass filter after
multiplication. However, because the output frequency is
high, this positive-only real power information is accumulated
The F 1–4 frequencies allow complete coverage of this range of
output frequencies (F1, F2). When designing an energy meter,
the nominal design voltage on Channel V2 (voltage) should be
set to half-scale to allow calibration of the meter constant. The
current channel should also be no more than half scale when
the meter sees maximum load. This allows overcurrent signals
and signals with high crest factors to be accommodated. Table 9
shows the output frequency on F1 and F2 when both analog
inputs are half scale. The frequencies in Table 9 align very well
with those in Table 8 for maximum load.
Table 9. F1 and F2 Frequency with Half-Scale AC Inputs
Frequency on F1 and F2—
over a much shorter time. Therefore, less averaging is carried
S1
S0
F 1–4 (Hz)
CH1 and CH2 Half-Scale AC Input 1
out in the digital-to-frequency conversion. With much less
averaging of the positive-only real power signal, the CF output
is much more responsive to power fluctuations (see the signal
processing block diagram in Figure 15).
0
0
1
1
0
1
0
1
0.86
1.72
3.43
6.86
0.051 × F 1
0.051 × F 2
0.051 × F 3
0.051 × F 4
0.044 Hz
0.088 Hz
0.176 Hz
0.352 Hz
1
Values are generated using the nominal frequency of 450 kHz.
Rev. A | Page 15 of 20
相关PDF资料
ADE7769ARZ-RL IC ENERGY METERING 1PHASE 16SOIC
ADM8843ACPZ-REEL7 IC LED DRVR WHITE BCKLGT 16LFCSP
ADP1653ACPZ-R7 IC LED DRVR PHOTO FLASH 16-LFCSP
ADP1712-EVALZ BOARD EVALUATION ADP1712
ADP1720-EVALZ BOARD EVAL FOR ADP1720-ADJ
ADP2140CPZ-REDYKIT REDYKIT 2 BOARDS ADP2140ACPZ
ADP3110AKRZ-RL IC MOSFET DRIVER DUAL 12V 8SOIC
ADP3120AJCPZ-RL IC MOSFET DRIVER DUAL 12V 8-DFN
相关代理商/技术参数
ADE7769 制造商:AD 制造商全称:Analog Devices 功能描述:Energy Metering IC with Integrated Oscillator and No-Load Indication
ADE7769AR 制造商:Analog Devices 功能描述:Energy Measurement 16-Pin SOIC N
ADE7769AR-REF 制造商:AD 制造商全称:Analog Devices 功能描述:Energy Metering IC with Integrated Oscillator and No-Load Indication
ADE7769AR-RL 制造商:Analog Devices 功能描述:Energy Measurement 16-Pin SOIC N T/R 制造商:Analog Devices 功能描述:ENERGY MEASUREMENT 16SOIC - Tape and Reel
ADE7769ARZ 功能描述:IC ENERGY METERING 1PHASE 16SOIC RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7769ARZ-RL 功能描述:IC ENERGY METERING 1PHASE 16SOIC RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7816 制造商:AD 制造商全称:Analog Devices 功能描述:Six Current Channels, One Voltage Channel
ADE7816ACPZ 功能描述:IC POWER METER 3 PHASE 40LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*